ICU Monitors

This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP.

 It integrates parameter measuring module, display and recorder in one device to form a compact 

and portable device. At the same time, its built in replaceable battery provides convenience for 

patient moving.

 

Features
  • Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.

  • Be applicable for adult, pediatric and neonatal.

  • Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in printer,  curving handle, moving bracket and hanging bracket are optional.

  • Operation interface with Chinese and English. Finish all operations by keys and knobs. 

  • (Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.)

  • 12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm,     bed NO, clock, state and other information provided by the monitor synchronously.

  • Monitoring contents, scan speed, volume and output contents can be set optionally.

  • Storage of 480-hour trend data, and review of 40-second holographic waveform. 

  • Storage and review of 72-hour ECG waveform.

  • Function of NIBP review, storage for up to 2400 NIBP data.

  • Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.

  • Calculation of drug concentration.

  • Network: connecting with central station, other Bed observation and software updating. 

  • Connection mode: wireless and wired.

  • Built-in rechargeable battery for uninterrupted monitoring.

  • Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).

  • Analysis function for heart rate variability(HRV) (optional)

Performance

ECG

 

Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, avR, avL, avF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV HR Measuring and Alarm Range Range 15 ~ 300 bpm  Accuracy ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm
 

CMRR

 

Monitor ≥ 100 dB
Surgery ≥ 100 dB
Diagnosis ≥ 60 dB
 

Bandwidth

 

Surgery 1 ~ 20 Hz(+0.4dB,-3dB)
Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB)
Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB)
Calibration Signal 1 mV (Vp-p), ±5%  Accuracy

 

ST Segment Monitoring   

Measuring and Alarm Range -0.6 mV~ + 0.8 mV

 

ARR

ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, 
TRIGEMINY,R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, 
PNP, PNC

 

Alarm

 Available

 

Review

 Available

 

Scan Speed for ECG 
Waveform is adjustable

 

12.5mm/s accuracy ±10%
25mm/s accuracy±10%
50mm/s accuracy±10%

Respiration 

 

Method R-F(RA-LL) Impedance 
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range 0.3~5.0Ω
Baseline Impedance Range 100Ω– 2500Ω
Bandwidth 0.3 ~ 2.5 Hz
 

Resp. Rate

 

Measuring and Alarm Range 0~120rpm
Resolution 1 rpm
Measuring Accuracy ±2 rpm
Alarm Accuracy ±3rpm
Apnea Alarm 10 ~ 40 S
 

NIBP

Method Oscillometry
Mode Manual, Auto, continuous 
Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /
90/120/240/480/960 Min
Measuring Period in Continuous Mode 5 Min
Measuring and Alarm Range 10~270mmHg
Alarm Type SYS, DIA, MEAN
 

Resolution

 

Pressure 1mmHg
Cuff Pressure ±3 mmHg
Accuracy ±10% or ±8mmHg, which is greater
Over-pressure Protection:
Adult Mode 315±10 mmHg
Pediatric Mode 265±10 mmHg
Neonatal Mode 155±10 mmHg
 

SpO2

Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy   70% ~ 100% ±2% 0% ~ 69% unspecified
 

Pulse Rate(PR)

 

Measuring and Alarm Range 0~250bpm
Resolution 1bpm
Measuring Accuracy ±2bpm or ±2%, which is greater
Alarm Accuracy ±2bpm
 

TEMP

Channel dual-channel
Measuring and Alarm Range 0 ~ 50°C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization Interval about 1 Sec.
Average Time Constant < 10 Sec.
Alarm responding Time ≤2min
 

EtCO2

Method Sidestream or Mainstream 
Measuring Range for CO2 0~150mmHg
Resolution for CO2:
0.1 mm Hg 0 to 69 mm Hg
0.25 mm Hg 70 to 150 mm Hg

Accuracy for CO2:  0 – 40 mm Hg ±2 mm Hg
                    41 – 70 mm Hg ±5%
                    71 – 100 mm Hg ±8%
                    101 – 150 mm Hg ±10%
                    Respiration Rate>80BPM ±12%
                    AwRR Range 2~150 rpm
                    AwRR Accuracy  ±1BPM
                    Apnea Alarm Available
 

IBP

Channel dual-channel
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range -50~350 mm Hg
Resolution 1 mm Hg
Accuracy ±2% or 1mm Hg, which is greater
 

Physical Characteristic

 

Dimension 310×140×263(mm)

Net weight 3.8Kg

 

Accessories

 

1) Adult SpO2 probe(5-pin)

2) Adult NIBP cuff

3) Extending tube for blood pressure

4) ECG lead

5) ECG electrode

6) Temperature probe

7) Power cord

8) Thermal recording paper(optional)

9) User Manual

                      Back to Home page